If the response code is not mentioned in the expected response code(s), the user will receive alert notifications. Expected response codeĬan users validate the response code or not receive any notifications in the case of failure codes if they mandate response codes at the web server end (that could be an error in general)?Įven if the configured response code is an error in general, users will be able to compare the response code to the configured expected Response Code and will not receive any alert notifications. You want to monitor the response time and availability of HTTP/HTTPS synthetics.Ĭonfigure HTTP/HTTPS synthetic monitor and check the availability of the webserver to handle requests. For more information, see Modifying Threshold Values. To stop the generation of false alerts even in the absence of monitoring issues, set a value greater than or equal to one while configuring component threshold values for. Server certificate:/ 'Ĭurl -mail-from -mail-rcpt Ĭurl -v the Response Time and Response Code of a website (HTTP/HTTPS)įalse alerts generated in the absence of monitoring issues ProtocolĬurl -I -L -header '' Ĭurl -I -L -header 'host:' PING Refer to the following table to validate the synthetic monitor status. Linux commands to validate synthetic monitors Scenario 4: Delay in synthetic metric data processing in the cloudĬontact Support to check the synthetic metric data. Contact Support to change the gateway status to UP. Scenario 3: Gateway is in Read-Only mode or DownĬheck for open alerts in Read-Only mode or in Down state in the gateway. Run the command monit restart webprobe to restart the application. Run the command: curl If the command does not generate a response in less than a minute, the webprobe is crashed or not running.Scenario 2: Synthetic application: webprobe in gateway crashed or not running If you are using Proxy, check the health status of Proxy. Metric values other than zero indicate that the gateway communication is lost. Run the command: curl and check the following metrics:. Synthetic graphs do not populate data in the following scenarios: Scenario 1: Network breakdown between the gateway and API server Synthetic graphs not populating on the User Interface (UI) False alerts generated in the absence of monitoring issues.Check the Response Time and Response Code of a website (HTTP/HTTPS).Linux commands to validate synthetic monitors.Synthetic graphs not populating on the User Interface (UI).Synthetic Monitor Troubleshooting On this page
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |